Coffee Machine Install Guide | Arden Coffee Sales Limited
Print

Install Guide

Install Guide

Above the picture will help you understand how the machine is installed, also what services you need to put in before we can install.

Photo of a working machine

Electrical

Standard 13 amp plug socket needed for a 1 group or a two group coffee machine.

20amp socket (supplied by Arden Coffee) for 2 or 3 group fast boil machine. For a fast boil 2 group for a busy site, will need to be on a B20 in the main consumer unit board and the machine machine needs to be on its own circuit.

Water Supply

Water supply terminating in a standard washing machine isolation valve

Waste

1.25” or 1.5” with trap and 9” upstand directly below machine location. As an alternative, waste can be run into a bucket, which must be emptied regularly.

Work surface

Any work surface and sub structure strong enough to sustain the weight (as above), and sturdy enough not to move when group operation is taking place.
75mm diameter hole to be drilled centrally beneath coffee machine location for waste and water feed (also for power if fed from under the counter).

Our technicians are only authorised to drill access holes through timber worktops.
Please note: We do not drill access holes through the following work surfaces or cabinet structures:

  • Stainless Steel
  • Ceramics
  • Granite, Stone, Marble
  • Glass Structures
  • Corian

No space under work surface?

Is there a fridge or wine fridge in the way? Arden coffee has a special fitting kit so we can still fit the machine you like anywhere you like without going under the work surface!

No Plumbing in the building?

With our fast flow pump system you don’t need mains plumbing! Have any machine anywhere you like.

Photo of a Working Machine

A tyipcal two group dual steam is approximently 750mm wide, but you still need space to work the steam arms and make the drink….

You will need 1550mm in total, meaning 400mm each side to make the drink.

As you can see from the photo above, amount of room needed for two persons to operate an espresso machine at the same time. As you can see how both people operating the steam arms have a place to make the drink after they have foamed the milk. The left has space in front of the knock out box and the on the right has in front of the grinder.

Puting an espresso machine up to a wall or say a fridge at the steam arm side will dramaticlly effect how many people can use the machine at one time. Why have a two steam arm mahine and two group heads to poor 4 coffees when only one person can drive the coffee machine?

As you can see from the photo above, amount of room needed for two persons to operate an espresso machine at the same time. Looking at the photo also you can see how both people operating the steamer have a place to make the drink after they have foamed the milk. The Girl on the left has space in front of the knock out box and the girl on the left has in front of the grinder.

Electrical Requirements

Most 2 group coffee machine are 13amp (standard plug top) but some are higher power

see chart below. Always check serial plate and with Arden coffee before connecting supply.

Group Socket needed On its own circuit from main electrical board On/off
1 No - Standard plug top 13amp No, just need a standard wall socket - 2kw Standard wall socket
2 No - Standard plug top 13amp No, just need a standard wall socket - 2.8kw Standard wall socket
2 Blue 32amp Socket B20 - Based on 4kw Element Red cooker type 32amp
3 Blue 32amp socket B32 - Based on 6kw Element Red cooker type 32amp
4 Blue 32amp socket B32 -Based on 7kw Element Red cooker type 32amp

Blue 32 amp socket

City electrical factors accross the country sell the blue 32amp socket (as in the picture above)

Easy – Exchange machine on repairs and breakdowns

Safe – Working to British standard

Fast – To connect a new machine

Water Supply

Water supply terminating in a standard washing machine isolation valve. Situated within 1 metre (directly under machine location), not through walls!

Waste

Waste Pipe

1.25” or 1.5” with trap and 9” upstand directly below machine location


Bucket

As an alternative, waste can be run into a bucket, which must be emptied every day

Fast flow pump

No cold water supply around? This pump is perfect for vending and espresso machine to supply water at 3 bar pressure.

Print

Copyright Arden Coffee Sales Ltd 2015 All rights reserved. Web Design Chesterfield by CNS Media